LCA 40 T2 (C1:6) [B-Form] 40º

LCA
Model
LCA 40 T2 (C1:6) [B-Form] 40º

LONG CASED AXIAL DIRECT DRIVE FAN WITH CAST ALUMINUM IMPELLER

MANUFACTURING FEATURES:
• Reinforced fan casing manufactured in rolling steel sheet.
• Modular motor-impeller assembly.
• Cast aluminum impeller with variable pitch angle.
• Polyester powder finishing coat.
• Housing with motor access door for easy connection.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.

APPLICATIONS:
Designed for inline installation, they are suitable for:
• Air renewal in buildings and industries.
• Smoke extraction (max 50-60ºC).
• Maximum working temperature: 1ph 50ºC, 3ph 60ºC.

UNDER REQUEST:
• 100% reversible impeller.
• 60Hz fans and special voltages.
• Hot-dipped galvanised or stainless steel housing.

Fan

Max flow
9570 m³/h
Angle
40º
Weight
- Kg

ERP

Fan sheet
Fan type Axial fan
Installation category A - Fan in free inlet and free outlet conditions, and with a partition between the inlet and outlet areas
Efficiency category Static
VF A variable speed drive is not required
Motor power (kW) 1,5
Requirements 2026 Values
Max. efficiency (%) 41.28 46.35
Efficiency grade (N) 50 55.07
Maximum efficiency point data
Flow (m³/h) 5289.55
Static pressure (Pa) 454.21
Speed (rpm)
Absorbed power (kW) 1.478
Specific ratio 1.00