SCA 35 T4 (C1:6) [B-Form] 40º

SCA
Model
SCA 35 T4 (C1:6) [B-Form] 40º

SHORT CASED AXIAL DIRECT DRIVE FAN WITH CAST ALUMINUM IMPELLER

MANUFACTURING FEATURES:
• Plate axial fan with circular reinforced frame.
• Modular motor-impeller assembly.
• Cast aluminum impeller with variable pitch angle.
• Polyester powder finishing coat.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.

APPLICATIONS:
Designed for wall or duct installation, they are suitable for:
• Air renewal in buildings and industries.
• Smoke exhaust (maximum 50-60ºC).
• Maximum working temperature: 50ºC single phase, 60ºC three phase.

UNDER REQUEST:
• Supply impeller (air direction from impeller to motor), 100% reversible impeller.
• 60Hz fans and special voltages.
• Hot-dipped galvanized or stainless steel housing.
• Optional can be adapted an square plate to the frame, to transform it in an axial square frame version fan.

Fan

Max flow
3550 m³/h
Angle
40º
Weight
- Kg

ERP

Fan sheet
Fan type
Axial fan
Installation category
A Outlet and Inlet free discharge
Efficiency category
Static
VF No
Values Requirements 2015
Max. efficiency (%)
29.56 28.72
Efficiency grade (N)
40.84 40
Absorbed power (kW) 0.164
Flow (m³/h)
1955.28
Static pressure (Pa)
87.41
Speed (rpm)
Specific ratio
1.00