fan image
Model
CRFAX 800 T6 4KW Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

CRFAX 800 T6 4KW Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

ATEX ROOF FAN WITH ALUMINUM COWL

MANUFACTURING FEATURES
• Roof cowl made of aluminium
• Structure, roof base support and bird protection guard made of galvanised steel.
• High efficiency backward impeller with self-cleaning system of steel.
• ATEX asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.
• ATEX certified:            Motor Ex-d: II 3G EX-d IIC T4
                                      Motor Ex-e: II 3G Ex-e IIC T4
                                      Motor Ex-nA: II 3G/D Ex-nA IIC T3

APPLICATIONS
Ventilation in indoor environments classified as ATEX. Specially designed for roof installation, they are suitable for:
• Smoke extraction.
• Smoke emergency exhaust with motor outside the hazardous area.
• Air renewal in buildings and industries.
• Industrial and professional kitchen hoods.
• Maximum continuous operation temperature: 110ºC (fluide).
• Maximum ambient temperature: 50ºC

UNDER REQUEST

• 60Hz and special voltages.
• Atex classification for other areas

Fan

Max flow
27090 m³/h
Weight
205 Kg

Motor

Power
4 kW
RPM Motor
960
I max. 230 V
16,5
I max. 400 V
9,46
Size
132M
Weight
68 Kg
Efficiency
84 %
FP
0.74
CRFAX 800 T6 4KW Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

CRFAX 800 T6 4KW Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Dimensions scheme
A B aprox C D E F G H I K aprox
1134,6 1142,72 1035 840 9 453 468 50 31 593,72

CRFAX 800 T6 4KW Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Electrical scheme

CRFAX 800 T6 4KW

Model
INT 25 3P A
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
SFC 400 III 12A *
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
BTI 1015
Information
INCLINED ROOF FAN SUPPORT

MANUFACTURING FEATURES

• Inclined support for roof fans CRFP, CRE EEC, CRK, and the resulting fans combining with the KIT ARF and KIT ARFM

In the code, indicate the pitch instead of "XX"

UNDER REQUEST

• Specific inclination.

CRFAX 800 T6 4KW Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)

Spare parts scheme
Family Name Qty
3 TURBINE CTH3 801 D.38 LG x1

CRFAX 800 T6 4KW Zone 2: FAN (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc)