SHORT CASED AXIAL DIRECT DRIVE FAN WITH CAST ALUMINUM IMPELLER
MANUFACTURING FEATURES:
• Plate axial fan with circular reinforced frame.
• Modular motor-impeller assembly.
• Cast aluminum impeller with variable pitch angle.
• Polyester powder finishing coat.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.
APPLICATIONS:
Designed for wall or duct installation, they are suitable for:
• Air renewal in buildings and industries.
• Smoke exhaust (maximum 50-60ºC).
• Maximum working temperature: 50ºC single phase, 60ºC three phase.
UNDER REQUEST:
• Supply impeller (air direction from impeller to motor), 100% reversible impeller.
• 60Hz fans and special voltages.
• Hot-dipped galvanized or stainless steel housing.
• Optional can be adapted an square plate to the frame, to transform it in an axial square frame version fan.
C' (Mot.T.132) | C' (Mot.T.132) | C' (Mot.T.160L) | C' (Mot.T.160L) | C' (Mot.T.160M) | C' (Mot.T.160M) | C' (Mot.T.180L) | C' (Mot.T.180L) | C' (Mot.T.180L) | C' (Mot.T.180L) | C' (Mot.T.180M) | C' (Mot.T.180M) | E | E | O | O | ØA | ØA | ØB | ØB | ØD | ØD | ØJ | ØJ |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
655 | 655 | 762 | 762 | 718 | 718 | 794 | 794 | 794 | 794 | 756 | 756 | 425 | 425 | 16x22,5º | 16x22,5º | 1115 | 1115 | 1070 | 1070 | 1013 | 1013 | 12 | 12 |
CONSTRUCTION FEATURES
• Protective grille on the motor and propeller side to prevent objects from entering. For SCAP and SCA models, the RP grille is only applicable on the propeller side. The RP is also suitable for the HMR EVO range, both for intake and discharge (note that the grille is of different sizes depending on whether it is for intake or discharge)
• Constructed with electro-welded rod.
• Compliant with ROHS directive 2002/95/EC.
ON REQUEST
• Grille in 304 or 316 stainless steel with electropolished finish.
MANUFACTURING FEATURES
• Made of steel and protected against corrosion with polyester resin powder.
MANUFACTURING FEATURES
• For axial (inlet and outlet) and centrifugal (inlet) fans.
UNDER REQUEST
• Versions in stainless 304 and stainless 316.
MANUFACTURING FEATURES
• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.
MANUFACTURING FEATURES
• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0: from -50ºC to +200ºC in continuous and 400ºC/2h
MANUFACTURING FEATURES
• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:
Arrow (mm.) r.p.m.
20 mm >600 r.p.m.
30 mm >500 r.p.m.
• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.
APPLICATION
• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.
MANUFACTURING FEATURES
• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa
APPLICATIONS
• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.
Other sizes, consult us.