LCA
Model
LCA 56 T4/T8 (A2:9)

LCA 56 T4/T8 (A2:9)

LONG CASED AXIAL DIRECT DRIVE FAN WITH CAST ALUMINUM IMPELLER

MANUFACTURING FEATURES:
• Reinforced fan casing manufactured in rolling steel sheet.
• Modular motor-impeller assembly.
• Cast aluminum impeller with variable pitch angle.
• Polyester powder finishing coat.
• Housing with motor access door for easy connection.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.

APPLICATIONS:
Designed for inline installation, they are suitable for:
• Air renewal in buildings and industries.
• Smoke extraction (max 50-60ºC).
• Maximum working temperature: 1ph 50ºC, 3ph 60ºC.

UNDER REQUEST:
• 100% reversible impeller.
• 60Hz fans and special voltages.
• Hot-dipped galvanised or stainless steel housing.

Wentylator

Maksymalny przepływ
14710 m³/h
LCA 56 T4/T8 (A2:9)
Loading...
Punkt projektowy
Loading...
Punkt Obsługi
Loading...
Punkt alternatywny

LCA 56 T4/T8 (A2:9)

Dimensions scheme
E E O O ØA ØA ØB ØB ØD ØD ØJ ØJ
560 560 12X30º 12X30º 646 646 620 620 559 559 12 12

LCA 56 T4/T8 (A2:9)

Electrical scheme

LCA 56 T4/T8 (A2:9)

Model
RP 56
Information
OSŁONA WLOTU/WYLOTU
SIATKA OCHRONNA NA WLOCIE I WYLOCIE Siatka ochronna na wlocie i wylocie. Specjalnie zaprojektowana dla ochrony przed kontaktem z obracającym się wirnikiem i przedostawaniem się przedmiotów. Wykonanie ze spawanego drutu metalowego. Zgodność z Dyrektywą Unii Europejskiej ROHS 2002/95/EC (Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipments – ograniczenie stosowania niektórych niebezpiecznych substancji w wyposażeniu elektrycznym i elektronicznym)
Model
MFLCA 56
Information
CASE FANS MOUNTING SUPPORT

MANUFACTURING FEATURES

• Made of steel and protected against corrosion with polyester resin powder.

Model
AC 560
Information
CONNECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
BA-400 56
Information
ZŁĄCZE PRZECIWDRGANIOWE 400ºC/2H

KOŁNIERZ ELASTYCZNY O ODPORNOŚCI TEMPERATUROWEJ 400ºC/2H Kołnierz elastyczny dla uniknięcia zjawiska przenoszenia się wibracji do instalacji.

Model
BAD 14
Information
CIRCULAR-CIRCULAR ANTI-VIBRATION FLANGE

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0: from -50ºC to +200ºC in continuous and 400ºC/2h

Model
KIT ARFM 56
Information
AXIAL ROOF FAN KIT - METALLIC

Set to install long cased axial fans on the roof :  LCAP,  LCA ...

It is composed by a roof cowl made of galvanized steel, a roof base support and bird protection guard with powder finishing coat.

Model
KIT ARF 56
Information
AXIAL ROOF FAN KIT

Set to install long cased axial fans on the roof :  LCAP,  LCA ...

It is composed by a roof cowl made of reinforced fiberglass, a roof base support and bird protection guard with powder finishing coat.

The kit musn't be installed if the air speed is higher than 13 m/s.

Model
INT (GENERIC)
Information
WYŁĄCZNIK BEZPIECZEŃŚTWA
WYŁĄCZNIK BEZPIECZEŃSTWA Wyłącznik bezpieczeństwa start-stop. Wykorzystywany do zatrzymywania wentylatorów przed przystąpieniem do wykonywania prac serwisowych lub konserwacyjnych. Zgodność z wymogami normy IEC 947-3. Stopień ochrony IP65.
Model
AVS (GENERIC)
Information
ANTI-VIBRATION SPRING BLOCK

MANUFACTURING FEATURES

• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:

Arrow (mm.)          r.p.m.
    20 mm          >600 r.p.m.
    30 mm          >500 r.p.m.

• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.

APPLICATION

• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.

Model
SIL-C 560/560
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.