LOW PRESSURE CENTRIFUGAL FAN WITH DOUBLE INLET FORWARD CURVED IMPELLER DIRECT DRIVE
MANUFACTURING FEATURES:
• Galvanised steel sheet housing.
• Double inlet forward curved impeller in all models.
Turbine fiber reinforced glass sizes 7-7, 9-9, 10/10 and 12/12. Other models in galvanized sheet.
• Supplied with mounting feet (included in price).
•Exclusive system fixing motor and turbine fan by flexible arms silent blocks to avoid any vibration. Arms in compliance with ROHS regulations 2002/95 / EC (Restriction of Hazardous Substances in electrical and electronic equipment)
•Closed motors specially designed : extruded aluminum housing, all protected inside the terminal box, built-in motor with IP65 connections.
•Motor with IP55 protection and Class F insulation standard voltages: 230V 50Hz in single phase and 230 / 400V 50Hz three-phase.
•Single phase voltage controllable. Adjustable phase models suitable for inverter.
APPLICATIONS:
Designed for assembly in equipment:
• Ventilation boxes and air handling units.
• Centrifugal heaters.
• Industrial and professional kitchen hoods.
• Maximum working temperature: 50ºC.
UNDER REQUEST
• Impeller made of galvanized steel sheet.
• assembled
A | B màx | C | D | E | F | G | H | I | J | N | X |
---|---|---|---|---|---|---|---|---|---|---|---|
329 | 368 | 359 | 350 | 70,5 | 20 | 464 | 214 | 420 | 198 | 291 | 220 |
MANUFACTURING FEATURES
• Specially designed for sinus wave speed control. Only available for single phase fans.
• Terminal wiring.
• Minimum speed adjustable and potentiometer speed control.
• Sealed box IP-54 box. Light switch pilot.
• EMC filter according to the En55014 Standard.
MANUFACTURING FEATURES
• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.
*Máx. thermal current air (A)
MANUFACTURING FRATURES
• Galvanized protection grid on the outlet side to avoid the entry of objects and contact with the impeller.
MANUFACTURING FRATURES
• Motor side protection guard specially designed for low pressure direct driven fans.
• Manufactured in galvanised steel.
MANUFACTURING FRATURES
• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.
Nº | Family | Name | Qty |
---|---|---|---|
1 | CASING | BD10/10 | x1 |
2 | IMPELLER | PA6 BD10/10 | x1 |
3 | MOTOR+SUPPORTS | BD10M6 STC | x1 |
3 | MOTOR | BD M6 0,19kW 230V | x1 |