fan image
Model
HPZA 800 T4 4kW

HPZA 800 T4 4kW

HIGH PRESSURE FAN WITH HIGH RADIAL IMPELLER DIRECT DRIVE IN Fe360 SHEET

 

MANUFACTURING FEATURES:

• Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average film thickness of 70 microns. Average heat resistence of coating is 180ºC with peaks of 200ºC.
• Fully welded housing.
• High efficiency simple inlet straight blade impeller made of Fe360 sheet statically and dynamically balanced.
Impellers are painted with polyester primer that resists temperatures up to 300ºC.
• Standard asynchronous squirrel-cage motor with IP-55 protection and class F insulation. Manufactured with standard voltages: 230/400V 50Hz in three phase motors up to 4kW and 400/690V 50Hz for higher powers.
• Standard orientation LG270.
• It allows adjusting the orientation locally from models 400 to 630. Models sizes from 710 to 1000 size the orientation is fixed.

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Industrial applications, extraction or injection of air.
• Cooling of machines and parts.
• Clean and dusty air transport.
• Exhaust after filters, separators and cyclones.
• Pneumatic transport.
• Maximum working temperature: carried air: 130ºC, ambient: 60ºC.

UNDER REQUEST

· Fans for 60Hz and special voltages.
· 2 speed motor.
· C4 or C5 coating painting
· Hot dip galvanized
· Special steel (Cor-Ten A, Hardox...)
· Inox 304 (normal or electropolished finish)
· Inox 316 (normal or electropolished finish)
· Cooling wheel
· Anticaloric paint
· Reinforced housing
· Fully welded housing (waterproof)
· Insulated housing
· Split casing (for big sizes)
· Inspection door to facilitate maintenance and cleaning
· Drain plug.
· Airtight axle
· Frontal foot
· Double suction flange
· Available in the following versions:
    - Non-sparking air passage and standard motor.
    - ATEX II3GD Ex_na
    - ATEX II3G Ex_e
    - ATEX II3GD Ex_d
· Other brands of motors.
· Orientation: RD0, RD45, RD90, RD135, RD180, RD225, RD270, RD315, LG0, LG45, LG90, LG135, LG180. LG225, LG315.

Fan

Flow
1800 m3/h

HPZA 800 T4 4kW

Dimensions scheme
A B C D E F G H2 I L M N O P d d1 d2 N1XØ1 Ø3 a b a1 b1 a2 b2 n1xp n2xp N2XØ2 S X D1 S1 X1 H D2 S2 X2 D3 S3 X3 D4 S4 X4 D5 S5 X5 H1 D6 S6 X6 O6 D7 S7 X7
78 505 1170 530 1264 551 72 710 197 49 276 30 289 324 255 292 325 8x10 12 185 131 219 165 255 201 - 1x112 6x12 640 554 679 554 530 710 622 545 854 640 530 679 592 854 622 554 679 640 710 545 622 592 324 854 592 545

HPZA 800 T4 4kW

Electrical scheme

HPZA 800 T4 4kW

Model
ISOSW 25A 1V
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped with an auxiliary contact.
• Useful for switching off the current before handling the fan.

Model
FLEX FIRE 25
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
PG8 255x8
Information
INLET PROTECTION GUARD FOR CENTRIFUGAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.

Model
PG4 185x131
Information
OUTLET PROTECTION GUARD FOR FANS

MANUFACTURING FRATURES

• Galvanized protection grid on the outlet side to avoid the entry of objects and contact with the impeller.

Model
S2R 185x131-250
Information
CIRCULAR OUTLET CONNECTION FLANGE

MANUFACTURING FEATURES

• Connection to be fitted in the centrifugal fans outlet.
• Manufactured in galvanized steel.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
FCCF 8
Information
CIRCULAR-CIRCULAR ANTI-VIBRATION FLANGE

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0: from -50ºC to +200ºC in continuous and 400ºC/2h

Model
CCF 250
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
FSCD 400 III 12A *
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

FSCD 230: Entrance 230V I, exit 230V III
FSCD 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

HPZA 800 T4 4kW

Spare parts scheme
Family Name Qty RPM Angle
2 TURBINE AAZA 800 T4 4kW LG x1 - -
3 INLET CONE AAZA-AAZZA 800 x1 - -
4 MOTOR 4KW T4 B3 230/400V IEC112 x1 - -