fan image
Model
BCU 800 T6 4KW

BCU 800 T6 4KW

CENTRIFUGAL DIRECT DRIVE FAN WITH BACKWARD CURVED IMPELLER IN CASING

MANUFACTURING FEATURES

• Casing:
- Made of galvanised steel sheet with upstream and downstream connecting flanges and access doors.
• Motor support:
- Galvanised steel plate, motor with flanges fixed on 2 poles. Removable plate/support/impeller set.
• Impeller:
- Backward impeller with self-cleaning system, in galvanised steel, dynamically balanced.
- Direct drive on the motor shaft.
• Motor:
- Three phase motor with IP-55 protection and F class insulation. Manufactured with standard voltages for one speed motors:
230/400V 50Hz up to 4 Kw and 400/690V 50Hz for higher powers of 4 and 6 poles.
2 speed motors:Dahlander

APPLICATIONS

• Ventilation in technical, industrial or commercial facilities.

Fan

Max flow
25310 m³/h
Weight
363 Kg

Motor

Power
4 kW
RPM Motor
960
I max. 230 V
16,5
I max. 400 V
9,46
Size
132M
Weight
68 Kg
Efficiency
86.8 %
FP
0.72
BCU 800 T6 4KW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

BCU 800 T6 4KW

Dimensions scheme
A B C D E H I K L L1 L2
1200 1200 1200 1656,5 456,5 374 413 26 1095,7 440,5 653,7

BCU 800 T6 4KW

Electrical scheme

BCU 800 T6 4KW

Model
INT 25 3P A
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
INT 400 25A 3P
Information
SAFETY SWITCH FOR 400ºC/2h

Safety switch for local disconnection of 400ºC/2h ventilation equipments according to UNE-EN 12101-3.
Suited for direct control of motor in AC 3 operation category
Equips two auxiliary contact.

Model
EI DHUMAT 800
Information
OUTLET FLANGE FOR BCU

MANUFACTURING FEATURES

• Connection flange for rectangular outlet of BCU, to make the connection to a circular duct easier.
• Made of galvanized steel.

Model
DKF 710-800
Information
BCU FEET KIT

MANUFACTURING FEATURES

• Support made of galvanized steel.

Model
VIS DHUMAT 710-800
Information
OUTDOOR FLANGE WITH BIRD GUARD FOR BCU

MANUFACTURING FEATURES

• Outdoor flange with bird guard for BCU.
• Made of galvanized Steel.

Model
SFC 400 III 12A *
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

BCU 800 T6 4KW

Spare parts scheme
Family Name Qty
1 MOTOR 4KW T6 B3 230/400V x1
3 INLET CONE ED11 800 x1