Product out of catalogue
fan image
Model
MPFI 28 T2 1,1kW

MPFI 28 T2 1,1kW

MEDIUM PRESSURE FAN WITH FORWARD CURVED IMPELLER DIRECT DRIVE IN CAST ALLUMINUM HOUSING

MANUFACTURING FEATURES:

• Cast aluminum housing.
• Cast aluminum impeller.
• Polyester powder finishing coat.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz in single phase motors and 230/400V 50Hz in three phase motors.
• Standard position LG 270.

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Industrial applications, extraction or injection of air.
• Cooling of machines and parts.
• Clean and slightly dusty air transport.
• Maximum working temperature: carried air: 130ºC, ambient: 60ºC.

UNDER REQUEST:

• 60Hz fans and special voltages.
• Position: LG 0, LG 45, LG 90, LG 135, LG 180, LG315.

Fan

Max flow
1460 m³/h
Weight
20 Kg

Motor

Power
1,1 kW
RPM Motor
2800
I max. 230 V
4,05
I max. 400 V
2,33
Size
80
Weight
16 Kg
Efficiency
82.7 %
FP
0.85
MPFI 28 T2 1,1kW
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

MPFI 28 T2 1,1kW

Dimensions scheme
A C D D1 D2 D3 D4 D5 D6 E F G H I J K L M P Q U V W X Y Z
275 125 168 440 470 468 605 558 516 505 393 230 166 290 130 182 160 100 140 162 10,2 20 113 13 M6 187 518 460 406 393 518 460

MPFI 28 T2 1,1kW

Electrical scheme

MPFI 28 T2 1,1kW

Model
INT 25 3P A
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
RA 14/5
Information
INLET PROTECTION GUARD FOR CENTRIFUGAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of galvanised steel models 7,9, 10, 12 and 15. And the rest of models with polyester powder finishing coat.

Model
BA-400 15/16
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
AC 130
Information
CONNECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
RBS 28
Information
OUTLET PROTECTION GUARD

MANUFACTURING FRATURES

• Outlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of steel and protected against corrosion with polyester resin powder.

Model
SFC 230 I 4,2A *
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
SFC 400 III 3,6A *
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

MPFI 28 T2 1,1kW

Spare parts scheme
Family Name Qty
1 BASE SUPPORT MOTOR MA28 x1
2 MOTOR 1,1kW T2 B14 230/400V x1
3 TURBINE MA28 LG x1
4 CASING MA28 x1